ALTAIR® 5X Multigas Detector

The ALTAIR 5X Gas Detector is capable of measuring up to 6 gases simultaneously and is now available with integrated PID sensor for VOC detection. Driven by advanced MSA XCell® Sensor Technology,  the ALTAIR 5X Gas Detector delivers  faster response time, better stability, accuracy, longer service life, and cost savings over the life of the instrument.

Interactive Simulator

 

Part Number
Description
10115118
10115118

10115119
10115119

10115141
10115141

10116926
10116926

Length: 0.050 M (1.969 IN)
Width: 0.166 M (6.535 IN)
Height: 0.079 M (3.110 IN)
Weight: 0.463 KG (1.021 LB)
Size: N/A
Color: CHARCOAL

10116928
10116928

Length: 0.050 M (1.969 IN)
Width: 0.166 M (6.535 IN)
Height: 0.079 M (3.110 IN)
Weight: 0.463 KG (1.021 LB)
Size: N/A
Color: CHARCOAL

10145627
10145627

10177343
10177343

10177344
10177344

10178973
10178973

10178974
10178974

10179955
10179955

10180979
10180979

10180980
10180980

10181284
10181284

10181851
10181851

10181852
10181852

10182528
10182528

10183629
10183629

10184221
10184221

10184770
10184770

10185688
10185688

10192100
10192100

10192654
10192654

10192656
10192656

10193041
10193041

  • Detects combustible gases in LEL and/or volume percentage range, oxygen, carbon monoxide, carbon dioxide, hydrogen sulfide, sulfur  dioxide, ammonia, chlorine, VOCs,  and many others depending upon sensor configuration.
  • Rugged overmolded polycarbonate housing provides unsurpassed durability, including ability to survive 10-ft. (3m) drop; IP65-certified.
  • Field-proven integral pump provides consistent gas flow, eliminating concerns of externally-attached components.
  • High performance XCell Sensors last longer:
    • Typical life greater than 4 years for combustible, O2, CO/H2S, SO2, CO/NO2 and CO (high concentration) sensors.
    • Typical life greater than 3 years for NH3 and Cl2 sensors.
    • Most sensor response and clear times <15 seconds.
  • Less calibration gas used:
    • Requires about half of test gas typically used for calibration and bump tests.
    • Rapid bump test gives results in less than 10 seconds for most common sensor configurations.
    • Span calibration time of 60 seconds for most common sensor configurations.
  • MotionAlert feature option tells others that user has become immobile.
  • InstantAlert feature provides manual alarm to alert others as to a potentially hazardous situation.
  • PID option allows for accurate, reliable VOC response with programmable reference factors.
  • Large buttons and bright display provide easy operation, even when users wear gloves.
  • Exclusive end-of-sensor warning cautions users when unit's sensor nears end-of-life.
  • Versatile MSA Link™ Software allows users to transmit data to a computer.
  • Compatible with GALAXY® GX2 Test System and MSA Link Pro Software for fleet management.
  • Wireless bluetooth included standard.

Related Resources

Markets: Construction, Fire Service, General Industry, Oil & Gas, Utilities
Applications: Confined Space

Approvals subject to change without notice and may differ based on configuration, part number and/or country.
Contact Customer Service or check approval label on product for specific approval information.